Wall display

The wall display is a full-screen, read-only view for TV and NOC screens: large status tiles grouped by host group, firing alerts and a clock, without navigation. When the fleet does not fit, it rotates through the groups every 20 seconds. Status is shown with text and icons, not only colour, so it stays readable from a distance and for people with colour vision deficiencies.

Open /display while signed in, or use a display token so the screen does not need an account:

  1. As an administrator, open Wall display and create a token, choosing the groups the screen may see (or all hosts).
  2. Copy the address, which is shown only once, for example https://monitor.example.com/display#token=hsd_…, and open it on the screen.

The token is in the URL fragment (the part after #), so it is never sent to web servers or written to their logs. It grants read access to the chosen groups only, and can be revoked at any time; the screen then shows that the token is no longer valid.

Tokens do not expire on their own: the same address keeps working after the screen’s browser restarts. If a screen is stolen or changes hands, revoke only that screen’s token; other screens are not affected. Creating one token per screen is therefore a good habit.

Options

Append options to the fragment with &:

OptionMeaning
rotate=<seconds>Time between groups (default 20)
theme=dark / theme=lightForce the colour scheme

Example: https://monitor.example.com/display#token=hsd_…&rotate=30&theme=dark

Tips for setting up a screen

  • Open the browser in kiosk mode, for example chromium --kiosk --noerrdialogs "https://monitor.example.com/display#token=…".
  • Turn off the screen’s sleep mode and screen saver.
  • With a self-signed certificate, make the screen’s browser trust it; otherwise the warning page appears after every restart.